Canada Power Company Manhole Repair Case Study

Innovative Solutions to Combat Water Infiltration Issues

Single Component Polyurethane saves costs and ensures long-lasting protection against manhole flooding and soil loss.

Problem

A Canadian power company faced a critical issue with water infiltration in a manhole at one of their switchyard facilities. The manhole, made from semi-flexible plastic,
had developed a gap between its structure and the utility lines entering it. Over time, this gap widened, leading to soil loss and the settlement of the soil surface around the
manhole. Periodic flooding of the manhole became a significant risk, raising concerns about potential power outages. To mitigate this, sump pumps were installed at the
bottom of the manhole, and the site required continuous 24/7 monitoring to manage the water infiltration.

Solution

Eco-Concrete Levelling was asked to provide a minimally invasive solution that would not require the utility service lines to be shut down. The team selected a flexible,
hydrophobic, single-component polyurethane foam as the ideal material to meet the project requirements. This foam, with an adjustable reaction profile, could be slowed
down to allow the material time to encapsulate the area before expanding to form a congruent seal. The low expansive pressure of the foam allowed for precise injections to take place adjacent to the manhole and utility lines without risking displacement or damage to the structure. In addition, the elasticity of the foam would help maintain a long-lasting seal that could accommodate the potential for future movement of the
filled gap.

Summary

The project involved permeation grouting using single-component polyurethane injected through three probes driven into the soil behind the manhole, on both sides, and just above the utility lines. A carefully measured volume of material was pumped to ensure thorough coverage and encapsulation. As the grouting process neared completion, material began to seep through the gaps, confirming full treatment of the area. To ensure complete coverage, an additional small volume of foam with an accelerated reaction time was injected directly into the gap from inside the manhole. The entire process was completed in just 45 minutes, effectively sealing the gaps and halting soil piping and water infiltration. Seeing the results, the client requested the same repair on a second manhole which was complete the same day in less time. This solution saved the client significant costs and resources that would have been required for ongoing 24/7 monitoring. Completely satisfied with the work, the client solicited estimates for additional areas to be completed in the future.

LEARN HOW TO START A SUCCESSFUL
CONCRETE RAISING BUSINESS

This site is protected by reCAPTCHA and the
Google Privacy Policy and Terms of Services apply.

Upcoming Discovery & Training Seminars

  • November 21-22, 2024  Manitowoc, WI
  • January 15-16, 2025  Las Vegas, NV

In 2 days, we teach you everything you need to know to start your own concrete raising company!

Cookies & Your Privacy

This website uses cookies to ensure you get the best experience on our website. More Information >